Richmond water heater pilot light won - Review Hoffmann Brothers' guide for how to light your water heater pilot light, perform basic checks, troubleshoot and access info for your specific brand. Careers (314) 664-3011 Book Now Air Conditioning

 
Oct 22, 2022 · Water heater pilot is not on; no hot water. Serial No. Q132038894. Model No. 6G40-36F3. I've tried to start the pilot light without success. The instructions affixed on the heater and the instructions … read more . Atandt 1 gig internet upload speed

Mar 20, 2022 · The article discusses the common problems that may arise with the Richmond water heater and their troubleshooting. These issues include condensation, yellow flame or soot, failure to light the main burner, rumbling noise, relief valve making popping noise, insufficient or no hot water, and too hot water. The reasons behind each issue and their solutions are elaborated upon in the article. Sep 4, 2022 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ... 07. Blocked Air Intake End-Note Richmond Water Heater Pilot Light Won’t Stay Lit [7 Easy Solutions] Your Richmond Water Heater pilot light won’t stay lit due to several reasons. These include a bad thermocouple, a tripped limit switch, plugged flammable vapor sensor, and a faulty gas valve.The pilot light is an important part of your Rheem water heater, but it might occasionally not light. Usually, relighting the light will restore your water heater’s functionality, but if the light won’t light, there’s a larger issue to address. Contents show 1 1. You Have a Blocked Gas Line 1.1 How To Fix 2 … Rheem Water Heater Pilot Light Won’t Light – Fixed Read More »Apr 25, 2010 · I could have found the troubleshooting guide by myself. If you replaced the thermocouple and it will not stay lit there are a couple of possibilities. Make sure the pilot flame envelops approximately 3/8 inch of the tip of the new thermocouple. When you go to light make sure you continue to hold down the button at least 30 seconds after the ... May 4, 2021 · Water Heater won't stay lit Ruud Water Heater Ph2-40-40f This is a pacemaker with the guardian system. The pilot and burner go out when the gas valve opens. The burner has a flame for a few seconds th … Apr 25, 2010 · I could have found the troubleshooting guide by myself. If you replaced the thermocouple and it will not stay lit there are a couple of possibilities. Make sure the pilot flame envelops approximately 3/8 inch of the tip of the new thermocouple. When you go to light make sure you continue to hold down the button at least 30 seconds after the ... Review Hoffmann Brothers' guide for how to light your water heater pilot light, perform basic checks, troubleshoot and access info for your specific brand. Careers (314) 664-3011 Book Now Air ConditioningMay 4, 2021 · Water Heater won't stay lit Ruud Water Heater Ph2-40-40f This is a pacemaker with the guardian system. The pilot and burner go out when the gas valve opens. The burner has a flame for a few seconds th … It is more than likely some kind of high limit sensor which would kick the pilot out should the water heater overheat. If your pilot is not staying lit with a new thermocouple, it may be this sensor. Try jumping the 2 leads going to the thermocouple adapter and see if it remains lit. If it does, it is this sensor that is bad.Usually, the pilot light isn’t staying lit on a Richmond water heater due to the bad thermocouple. It may also be due to a lack of combustible air, but this is less likely. Look to see if the thermocouple has been bent, damaged, or is too dirty, and take appropriate action.I've got a Richmond Water heater in a 2-flat that is giving me problems. A day ago I got a call that the water wasn't hot anymore so I went over to check it out. The pilot light was out so I lit it by holding down the button and hitting the piezo button. After a few clicks it lit up and stayed lit.Apr 9, 2020 · I'm not a professional. This is the one thing that's worked AMAZING to get my hot water heater pilot light to stay on! INCREDIBLE prices on AMAZON: https://a... January 24, 2023 by David. We’ll cover the following problems in this complete Richmond water heater troubleshooting guide: Condensation. Yellow soot. The main burner won’t light or stay lit. The pilot light won’t stay lit. Rumbling noise. Noise from the relief valve. No hot water or inadequate hot water.Begin by turning your pilot light off, if it is not already. Next, turn off the flow of gas to your furnace completely using the shutoff valve. It should be nearby or even on your furnace. Once you have done this, allow your furnace to cool down for at least 30 minutes so it is safe to open, then open the hatch covering your pilot light and ...Water heater pilot won't light. Richmond water heater, smelled for gas at end of tibe by burner and is present. Filter - Answered by a verified HVAC TechnicianHi Ellen I have a Richmond 6G30-32F1 gas hot water heater. that stopped working Thursday. the pilot was out so i lit it and tried to turn it on and everytime i tried to turn it on ot wou;d flameup then blow out. so Ive seen this before so I replavedf the thermocouplet/ mo problem. i tried to turn it on and it flamdd uo ran for aminute then cuts off it keeps dpoing this. what is my next step to tryI have a Richmond electronic iginition water heater model 5VP40E-1A, sometimes it lights and and works for a few days, sometimes I have to shut it down and then re-start it to get it to work, seen oth …If the water heater pilot light will not stay lid there are two main options, the first one is the Thermocouple, but if this one is working fine and you can ... A water heater pilot light that won’t stay lit is almost always caused by a bad thermocouple. It fails to send a signal to the gas valve to open up, meaning gas does no flow to the pilot and burner. It could also be caused by a faulty gas control valve or tripped thermal switch. If your water heater pilot won’t stay lit even after replacing ...The water heater pilot light is a small flame that ignites the gas burner on your water heater. When the water heater pilot light goes out, first try relighting it, following the directions on the water heater label. If the pilot doesn’t relight, if it goes out right after lighting or if it goes out repeatedly, by far the most common cause is ... 6. Below is a picture of the lighting instructions for your water heater taken from Rheem's website. Make sure to follow the lighting instructions carefully and do not skip any steps. This same instruction set should be available as a sticker on your unit. It looks like you do in fact have to depress the knob in order to turn it so avoid using ...Last night, I noticed that the pilot light was out and this morning when the plumber came to look at it he immediately told me what was wrong with it which is the gas control valve is bad. Said it would cost about $700 to fix so I called Menards and the plumbing associate informed me that the Richmond water heaters have a recall on them for ...Install a New Thermocouple. Insert the new thermocouple from the outside through the grommet or opening in the burner assembly manifold cover. Insert the thermocouple into its mounting bracket until it is fully seated or clicks into place. Position the thermocouple tip so that the pilot flame will envelop the top 3/8 to 1/2 inch of the ...May 24, 2013 · I am not a professional, just documenting how i repaired the hot water heater's pilot light to stay on. The solution was adjusting the thermocouple. You can ... I had a power outage at my house and coincidentally (?) my water heater pilot light went out. My Kenmore water heater is controlled by the Honeywell Gas Valve (part # 9007884), which contains the WV8840 Communication Port. The water heater wouldn’t re-light, but I noticed that the indicator was blinking four times in succession.If your gas water heater doesn’t stay lit, you may have a defective thermocouple. Most gas fired water heaters use a standing pilot to ignite the main burner. The gas for the pilot assembly is supplied by the main gas valve and is monitored by the thermocouple. The thermocouple is a heat sensing probe that is part of the pilot assembly and ...Install a New Thermocouple. Insert the new thermocouple from the outside through the grommet or opening in the burner assembly manifold cover. Insert the thermocouple into its mounting bracket until it is fully seated or clicks into place. Position the thermocouple tip so that the pilot flame will envelop the top 3/8 to 1/2 inch of the ...my Richmond 40 gal. hot water heater that's only 2 yrs old stopped working. I relit it, and it was fine for a few hours. it went out again and I considered t...Replaced Pilot assembly last week as pilot went out when burner shut off. Today I replaced the temperature control valve. Same thing, lit pilot, burner came on the after a heat cycle burner shut off as well as pilot. Trying an immediate restart only igniter worked after about 4 or 5 minutes was able to light the pilot. Then the whole episode ... 5. Energize The Gas Valve. Confirm that the pilot is lit visually. Continue holding the gas supply button for around 45 seconds to heat the thermocouple.Let the button go, and if the pilot stays lit, you are ready to turn ON the gas control knob.A thermocouple is a function on your water heater that senses the heat on the pilot light and allows gas to flow to the burner. A bad thermocouple will shut off gas to both the pilot and the burner, which is when people notice that the water heater pilot light is out. Your water heater pilot light works in concert with other parts.Jul 29, 2023 · Richmond Water Heater Pilot Light Won’t Stay Lit: A Detailed Discussion. As you can see from the table above, there are many reasons why the heater’s pilot light tends not to stay lit. And there are solutions for each problem. In the following part, I have discussed the issues in more detail and also shared how you can solve them. Slightly depress the gas control knob and turn clockwise to OFF position. Wait 5 minutes to clear out any gas. Stop and follow the safety precautions as above if you smell any gas. Go to the next step if you do not smell gas. Remove the outer door from the water heater. Do not attempt to remove the inner door.Richmond Water Heater Thermocouple Replacement: The How-To Steps. First off, determine which size and style of thermocouple you need for your Richmond water heater. Once you get the correct thermocouple for your water heater, follow the below step-by-step guide to replace the old thermocouple with a new one. 01. Shut Off The Gas SupplyI used this to repair my 40Gal Richmond LP water heater model 6G40-32PF1. The replacement gasket and mounting seal are superior that the one that came with the heater itself. The line lengths provided were more than enough to remount on my water heater.New Member. May 22, 2013, 08:52 PM. Richmond water heater pilot light won't stay lit. We have a Richmond 40 gal water heater. The sewage pipe in our basement recently overflowed, leaving about 2 inches of water in the basement. Once we got the mess cleaned up, we noticed we have no hot water. We checked the pilot on the hot water heater and ... I have a Richmond electronic iginition water heater model 5VP40E-1A, sometimes it lights and and works for a few days, sometimes I have to shut it down and then re-start it to get it to work, seen oth …Clean those first before doing anything else. It's routine maintenance that needs to be done in any case. You need to remove the pilot burner, take the pilot tubing off and remove the pilot orifice. Sometimes you can clean the pilot orifice with the wire from a wire brush. Use a wire brush to clean the pilot burner.Mar 1, 2010 · hayewe farm · #2 · Mar 1, 2010. Go to your local hardware or computer store and pick up a can of air used to clean computer keyboards. With the pilot off insert the air can tube in the end of the pilot tube and give it a couple of blasts of air. It may be you have an oxygen depletion unit that is dirty. Clean those first before doing anything else. It's routine maintenance that needs to be done in any case. You need to remove the pilot burner, take the pilot tubing off and remove the pilot orifice. Sometimes you can clean the pilot orifice with the wire from a wire brush. Use a wire brush to clean the pilot burner.Review Hoffmann Brothers' guide for how to light your water heater pilot light, perform basic checks, troubleshoot and access info for your specific brand. Careers (314) 664-3011 Book Now Air Conditioning It is more than likely some kind of high limit sensor which would kick the pilot out should the water heater overheat. If your pilot is not staying lit with a new thermocouple, it may be this sensor. Try jumping the 2 leads going to the thermocouple adapter and see if it remains lit. If it does, it is this sensor that is bad.Apr 12, 2021 · 6. Below is a picture of the lighting instructions for your water heater taken from Rheem's website. Make sure to follow the lighting instructions carefully and do not skip any steps. This same instruction set should be available as a sticker on your unit. It looks like you do in fact have to depress the knob in order to turn it so avoid using ... 2. If I understand correctly, your pilot flame is lighting correctly. But the main burner won't turn on because the electronics in the Gas Control Valve don't acknowledge the pilot is lit. There are two likely faults: Thermopile is not sensing the flame correctly, or. Circuit Board in the Gas Control Valve is defective.I used this to repair my 40Gal Richmond LP water heater model 6G40-32PF1. The replacement gasket and mounting seal are superior that the one that came with the heater itself. The line lengths provided were more than enough to remount on my water heater.1. Turn the gas valve to the "Pilot" setting and push down on it. Doing this starts the flow of gas into the tube that supplies the pilot light. If your water heater’s gas valve does not push down, look for a red control button near the valve. Hold this button down.Here is what to try. First, using the back end of a large screw driver, medium hard tap the gas control valve. Doing so may dislodge the tiny disk and the pilot will go out. If not, try again. If second attempt fails, turn off the control knob. Turn control dial to the OFF position, so the pilot does go out.Sep 25, 2021 · Have you tried cleaning/replacing your thermocouple and still no dice? Have you tried cleaning/replacing the pilot assembly and still nothing? My opinion is ... The Richmond Marathon ® water heater offers a LIFETIME warranty. The Marathon is a special water heater that has a seamless blow molded polybutene inner tank. It will not rust. The several inches of foam insulation give it up to 0.93 uniform energy factor. Tank sizes range from 15 gallons to 105 gallons to fit any household need.Jun 26, 2007 · I've got a Richmond Water heater in a 2-flat that is giving me problems. A day ago I got a call that the water wasn't hot anymore so I went over to check it out. The pilot light was out so I lit it by holding down the button and hitting the piezo button. After a few clicks it lit up and stayed lit. I installed a new Richmond water heater and worked good for like 4 - 5 days. then pilot light went and when i would try to ignite, pilot light would light but as soon as i replaced thermocoupler did t … read morePress and hold down the button. Listen for the click and ignition. Your igniter should light the gas directly if it is a hot surface ignition. You will know it is working if you feel the heat coming from the unit. Lighting an intermittent pilot ignition: Locate the igniter button and knob.Apr 25, 2010 · I could have found the troubleshooting guide by myself. If you replaced the thermocouple and it will not stay lit there are a couple of possibilities. Make sure the pilot flame envelops approximately 3/8 inch of the tip of the new thermocouple. When you go to light make sure you continue to hold down the button at least 30 seconds after the ... Feb 14, 2019 · A.O. Smith GVR 40 101 water heater had no spark on the pilot. Disassembled and cleaned the pilot light and thermocouple. Reassembled and fired it up on the f... Dec 4, 2018 · Find Thermo couopler for your Water Heater Here: https://www.repairclinic.com/Shop-For-Parts?query=water%20heater%20thermo%20coupleGas water heater pilot not... The number one reason the Richmond water heater pilot light won’t stay lit is an issue with the thermocouple. It can be dirty, bent, or damaged. You can solve this problem by cleaning it, adjusting its position, or replacing it. However, it’s not the only potential reason behind this issue.Jan 24, 2023 · January 24, 2023 by David. We’ll cover the following problems in this complete Richmond water heater troubleshooting guide: Condensation. Yellow soot. The main burner won’t light or stay lit. The pilot light won’t stay lit. Rumbling noise. Noise from the relief valve. No hot water or inadequate hot water. Dec 22, 2022 · Pilot light won't stay lit. Richmond 6G40-36F3 Installed 7/2021. ... My seven year old Richmond 6G40-32PF1 lp gas water heater pilot light won't stay lit after ... I've got a Richmond Water heater in a 2-flat that is giving me problems. A day ago I got a call that the water wasn't hot anymore so I went over to check it out. The pilot light was out so I lit it by holding down the button and hitting the piezo button. After a few clicks it lit up and stayed lit.The water heater pilot light is a small flame that ignites the gas burner on your water heater. When the water heater pilot light goes out, first try relighting it, following the directions on the water heater label. If the pilot doesn’t relight, if it goes out right after lighting or if it goes out repeatedly, by far the most common cause is ... It’s also a relatively inexpensive component. So, you won’t have to break the bank to replace it. You can check out our guide on why Richmond water heater pilot light won’t stay lit where we have broken down how to replace the thermocouple in nice and easy steps. 6. Faulty Pressure SwitchNov 28, 2009 · RickyM1118. Plumber. High School or GED. 29 satisfied customers. My seven year old Richmond 6G40-32PF1 lp gas water heater. My seven year old Richmond 6G40-32PF1 lp gas water heater pilot light won't stay lit after releasing button. The gas tank ran out of gas and was … read more. It’s also a relatively inexpensive component. So, you won’t have to break the bank to replace it. You can check out our guide on why Richmond water heater pilot light won’t stay lit where we have broken down how to replace the thermocouple in nice and easy steps. 6. Faulty Pressure SwitchIt's not always the thermocouple that is faulty. Many of these gas control valves can be easily fixed!! This is a very quick fix that anyone can do without c...For use on GE, Rheem, Ruud and Richmond FVIR water heaters with Delta/SIT gas valves; Genuine OEM replacement part; 1 year limited warranty; Fix your water heater with peace of mind using genuine Rheem parts; Easy to install; Call 1-800-432-8373 to ensure this is the correct part for your water heater; Durable construction for long life I am not a professional, just documenting how i repaired the hot water heater's pilot light to stay on. The solution was adjusting the thermocouple. You can ...Here is what to try. First, using the back end of a large screw driver, medium hard tap the gas control valve. Doing so may dislodge the tiny disk and the pilot will go out. If not, try again. If second attempt fails, turn off the control knob. Turn control dial to the OFF position, so the pilot does go out.Water heater pilot is not on; no hot water. Serial No. Q132038894. Model No. 6G40-36F3. I've tried to start the pilot light without success. The instructions affixed on the heater and the instructions for lighting do not match my heater: I see no door to open; no place to see the pilot to determine if it's lit The number one reason the Richmond water heater pilot light won’t stay lit is an issue with the thermocouple. It can be dirty, bent, or damaged. You can solve this problem by cleaning it, adjusting its position, or replacing it. However, it’s not the only potential reason behind this issue.A.O. Smith GVR 40 101 water heater had no spark on the pilot. Disassembled and cleaned the pilot light and thermocouple. Reassembled and fired it up on the f...I had a power outage at my house and coincidentally (?) my water heater pilot light went out. My Kenmore water heater is controlled by the Honeywell Gas Valve (part # 9007884), which contains the WV8840 Communication Port. The water heater wouldn’t re-light, but I noticed that the indicator was blinking four times in succession.Review Hoffmann Brothers' guide for how to light your water heater pilot light, perform basic checks, troubleshoot and access info for your specific brand. Careers (314) 664-3011 Book Now Air Conditioningmy water heater won't stay onOct 12, 2019 · Hi Ellen I have a Richmond 6G30-32F1 gas hot water heater. that stopped working Thursday. the pilot was out so i lit it and tried to turn it on and everytime i tried to turn it on ot wou;d flameup then blow out. so Ive seen this before so I replavedf the thermocouplet/ mo problem. i tried to turn it on and it flamdd uo ran for aminute then cuts off it keeps dpoing this. what is my next step to try Mar 1, 2010 · hayewe farm · #2 · Mar 1, 2010. Go to your local hardware or computer store and pick up a can of air used to clean computer keyboards. With the pilot off insert the air can tube in the end of the pilot tube and give it a couple of blasts of air. It may be you have an oxygen depletion unit that is dirty. The water heater pilot light is a small flame that ignites the gas burner on your water heater. When the water heater pilot light goes out, first try relighting it, following the directions on the water heater label. If the pilot doesn’t relight, if it goes out right after lighting or if it goes out repeatedly, by far the most common cause is ...It's easy to fix this water heater problem by yourself. I fixed mine and also decided to make a better video to help out more people who love DIY.- Pilot lig...Feb 15, 2021 · If your hot water heater has no spark at all, or the flame isn't staying on, give this video a watch for a couple super simple things to try. Repairing your ... I have a Richmond tankless water heater Model # RMTG-74PVN-1. I have a Richmond tankless water heater Model # XXXXX It was installed the summer of 2007. has operated proplem free until last week when it stopped working and flashing C7 on the remote.If the pilot will not stay lit on your gas water heater, then this is likely to be the problem.The water heater pilot light is a small flame that ignites the gas burner on your water heater. When the water heater pilot light goes out, first try relighting it, following the directions on the water heater label. If the pilot doesn’t relight, if it goes out right after lighting or if it goes out repeatedly, by far the most common cause is ...Slightly depress the gas control knob and turn clockwise to OFF position. Wait 5 minutes to clear out any gas. Stop and follow the safety precautions as above if you smell any gas. Go to the next step if you do not smell gas. Remove the outer door from the water heater. Do not attempt to remove the inner door.Jun 10, 2022 · It's not always the thermocouple that is faulty. Many of these gas control valves can be easily fixed!! This is a very quick fix that anyone can do without c... Dec 22, 2022 · Pilot light won't stay lit. Richmond 6G40-36F3 Installed 7/2021. ... My seven year old Richmond 6G40-32PF1 lp gas water heater pilot light won't stay lit after ... May 5, 2022 · I have a Richmond hot water heater with a Honeywell S8610U controller and a Honeywell VR8245M gas valve. The ignition sequence seams to start normally- pilot ignition, main burner ignition- then the m … Dec 8, 2016 · I have a Richmond rmtgl74pvn tankless water heater that has worked great for5 years but it stopped working just now. Won't light, looks like there is no power to the board but I've checked that. read more If the water heater pilot light will not stay lid there are two main options, the first one is the Thermocouple, but if this one is working fine and you can ...No hot water? If the pilot flame in your water heater keeps on going out or won't stay lit, then it could be a problem with the thermocouple or thermal cutof...

A water heater pilot light that won’t stay lit is almost always caused by a bad thermocouple. It fails to send a signal to the gas valve to open up, meaning gas does no flow to the pilot and burner. It could also be caused by a faulty gas control valve or tripped thermal switch. If your water heater pilot won’t stay lit even after replacing .... Bra victoria

richmond water heater pilot light won

Water heater,,,,6G40S34F3,,,pilot light won't stay lite. 4 years about. Richmond. Just happened today - Answered by a verified HVAC TechnicianThe Richmond Marathon ® water heater offers a LIFETIME warranty. The Marathon is a special water heater that has a seamless blow molded polybutene inner tank. It will not rust. The several inches of foam insulation give it up to 0.93 uniform energy factor. Tank sizes range from 15 gallons to 105 gallons to fit any household need. Pilot light won't stay lit when you turn knob from pilot to on, it goes out as soon as the knob pops up before you can turn it to on. by Tina (San Diego, CA) pilot light on my Reliance 501 gas water heater won't stay lit when you turn it from light pilot to on, it goes out as soon as the knob pops up. What do I do?Reopen the shutoff valve. Relight the pilot light. Turn the control valve to “on”. When the gas burner comes on, use a 50/50 dish soap/water mix to test the screw joints for air bubbles that indicate leaks. Note: When relit, the water heater pilot light flame should wrap around the thermocouple bulb.May 4, 2021 · Water Heater won't stay lit Ruud Water Heater Ph2-40-40f This is a pacemaker with the guardian system. The pilot and burner go out when the gas valve opens. The burner has a flame for a few seconds th … I installed a new Richmond water heater and worked good for like 4 - 5 days. then pilot light went and when i would try to ignite, pilot light would light but as soon as i replaced thermocoupler did t … read morePress and hold down on the gas control knob, or pilot set button. At the same time as you’re holding down the pilot switch, press on the piezo igniter. When you click the igniter, you should hear a “click” sound, indicating the spark igniting the pilot. Once the pilot light is on, continue pressing down on the pilot switch for a minute to ...Turn the gas off on the main shutoff valve that is supplying a water heater. Remove the cover plate at the bottom of the water heater, if possible. Locate the pilot tube connected to the gas valve with the nut and disconnect it. There is also a thermocouple attached. If needed, disconnect it too.Nov 28, 2009 · RickyM1118. Plumber. High School or GED. 29 satisfied customers. My seven year old Richmond 6G40-32PF1 lp gas water heater. My seven year old Richmond 6G40-32PF1 lp gas water heater pilot light won't stay lit after releasing button. The gas tank ran out of gas and was … read more. Feb 14, 2019 · A.O. Smith GVR 40 101 water heater had no spark on the pilot. Disassembled and cleaned the pilot light and thermocouple. Reassembled and fired it up on the f... Find Thermo couopler for your Water Heater Here: https://www.repairclinic.com/Shop-For-Parts?query=water%20heater%20thermo%20coupleGas water heater pilot not...If your gas water heater doesn’t stay lit, you may have a defective thermocouple. Most gas fired water heaters use a standing pilot to ignite the main burner. The gas for the pilot assembly is supplied by the main gas valve and is monitored by the thermocouple. The thermocouple is a heat sensing probe that is part of the pilot assembly and ...Jun 10, 2022 · It's not always the thermocouple that is faulty. Many of these gas control valves can be easily fixed!! This is a very quick fix that anyone can do without c... Turn the gas off on the main shutoff valve that is supplying a water heater. Remove the cover plate at the bottom of the water heater, if possible. Locate the pilot tube connected to the gas valve with the nut and disconnect it. There is also a thermocouple attached. If needed, disconnect it too.I had a power outage at my house and coincidentally (?) my water heater pilot light went out. My Kenmore water heater is controlled by the Honeywell Gas Valve (part # 9007884), which contains the WV8840 Communication Port. The water heater wouldn’t re-light, but I noticed that the indicator was blinking four times in succession.1. Turn the gas valve to the "Pilot" setting and push down on it. Doing this starts the flow of gas into the tube that supplies the pilot light. If your water heater’s gas valve does not push down, look for a red control button near the valve. Hold this button down..

Popular Topics